Applies to: Byonic, version 6.2 and later
Overview
From version 6.2, a modification in Byonic can carry a custom mass shift attribute. This lists one or more named mass deltas, so you can define custom neutral losses and gains directly in the modification syntax. This gives you more precise fragment annotation for modified peptides.
When a peptide fragment is matched, the engine scores and annotates any fragment containing a residue with that modification at each declared offset, in addition to the standard fragment ions.
This is useful for liable modifications, whereby the modification is displaced from the amino acid side chain during the fragmentation step.
Syntax
ModName/+Mass @AAs | fineControl | CustomMassShift{Label1:MassShift1, Label2:MassShift2}
| Element | Description |
|---|---|
ModName | Name of the modification |
+Mass | Mass of the modification in Da |
@AAs | Residue(s) the modification applies to |
fineControl | Fine control setting for the modification |
CustomMassShift{...} | One or more named mass deltas, each written as Label:MassShift |
Procedure
- Open the Byonic custom modification box.
- Enter the modification in fine control format, including the
CustomMassShiftblock. - Define each shift as
Label:MassShift, with a unique label and a positive or negative mass. - Separate multiple shifts with commas inside the braces*.
- Run the search.
*Start with the neutral losses you expect to dominate, rather than adding every possible loss. Each extra shift adds more theoretical peaks that can be penalized.
Example
This defines a modification named Foo (+100 Da) on serine and threonine residues.
For any matched fragment that contains a modified S or T, the scorer also looks for and annotates:
- FooWaterLoss: a −18.01 Da shift
- FooOxidation: a +15.99 Da shift
Notes
- Multiple
CustomMassShiftentries per modification are supported. Separate them with commas inside the braces. - Labels must be unique within a given modification’s
CustomMassShiftblock. - Mass shifts can be positive or negative.
- Custom shifts apply only to fragments that already contain at least one residue carrying the parent modification. Unmodified residues are unaffected.
Important: effect on the Byonic score
Adding custom mass shifts can lower the score of a peptide match. The Byonic score is the sum of benefits for theoretical fragment peaks found in the observed spectrum and penalties for theoretical peaks not found. When you define a custom neutral loss, the search also looks for those additional fragments. If they are not present in the spectrum, they count as missing peaks and reduce the score.
A lower score doesn’t mean the identification is wrong. Only define shifts that you expect to see for your modification and fragmentation conditions, and compare the annotated spectrum with and without the shifts before drawing conclusions.
Application areas
This feature is particularly useful when performing peptide mapping of:
- Antibody-drug conjugates (ADCs) with labile payloads
- GLP-1 peptides that contain a labile fatty acid
The example below shows how this feature was applied to the analysis of liraglutide, a synthetic GLP-1 peptide in which a palmitoyl group and a glutamic acid linker are attached to a lysine side chain. The MS2 spectrum contains peaks resulting from neutral losses of both the glutamic acid and the palmitoyl group. Once these losses are defined in the custom modification box using the required syntax**, the corresponding fragments are annotated in the spectrum.
** Palmitoyl / +367.272 @ K | rare2 | CustomMassShift{PalmitateLoss:-238.2297,SideChainLoss:-367.2723}